What was found
AIRCRAFT RETURNED TO FIELD. HYD RESERVOIR YELLOW SYS INOPERATIVE. FOLLOWED ECAM PROMPTLY WHICH CALLED FOR YELLOW ENG PUMP & PTU OFF. REPLACED GND SERVICE MANIFOLD & LEAK CHECK SYS IAW AMM 29-19-41, NO LEAK FOUND. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT RETURNED TO FIELD. HYD RESERVOIR YELLOW SYS INOPERATIVE. FOLLOWED ECAM PROMPTLY WHICH CALLED FOR YELLOW ENG PUMP & PTU OFF. REPLACED GND SERVICE MANIFOLD & LEAK CHECK SYS IAW AMM 29-19-41, NO LEAK FOUND. OK FOR SERVICE.