What was found
PIT - DURING SCHEDULED STRUCTURES VISIT, FOUND 7.5 INCH CRACK IN AFT SIDE OF FORWARD PRESSURE BULKHEAD BETWEEN STA 72 AND STA 73. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR PLATE PER SRM 53-11-00, PAGE 2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING SCHEDULED STRUCTURES VISIT, FOUND 7.5 INCH CRACK IN AFT SIDE OF FORWARD PRESSURE BULKHEAD BETWEEN STA 72 AND STA 73. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR PLATE PER SRM 53-11-00, PAGE 2. (X)