As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PIT - DURING SCHEDULED SIP VISIT, FOUND 1.5 INCH CRACK IN REAR PRESSURE BULKHEAD STATION 17065 HORIZONTAL BEAM NR 3 AT BL 425 RT HIGH FREQUENCY EDDY CURRENT INSPECTION SIP REF 53-10-03. STOP DRILLED CRACK AND INSTALLED ANGLE AND DOUBLER REPAIR PER USAIR EA 30104.