What was found
PIT - DURING AN FC-6 CHECK INSPECTION, FOUND .75 INCH CRACK IN RIGHT NR 2 WINDOW POST (TYPE 3) REF SIP 53-10-08. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR PER USAIR TYPICAL REPAIR 53-10-01 REV A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING AN FC-6 CHECK INSPECTION, FOUND .75 INCH CRACK IN RIGHT NR 2 WINDOW POST (TYPE 3) REF SIP 53-10-08. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR PER USAIR TYPICAL REPAIR 53-10-01 REV A. (M)