What was found
YYC - DURING FC-06 CHECK, FOUND 1 INCH BY 2 INCH CORRODED AREA TOP OF FLOOR BEAM AT STA 3840, BL 600R. REMOVED, FABRICATED NEW SEAT RAIL SECTION AND INSTALLED PER SRM 53-11-05, PAGE 14, FIGURE 4, ITEM 80. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
YYC - DURING FC-06 CHECK, FOUND 1 INCH BY 2 INCH CORRODED AREA TOP OF FLOOR BEAM AT STA 3840, BL 600R. REMOVED, FABRICATED NEW SEAT RAIL SECTION AND INSTALLED PER SRM 53-11-05, PAGE 14, FIGURE 4, ITEM 80. (X)