What was found
YYC - DURING FC-06 CHECK, FOUND 30 MM BY 20 MM CORRODED AREA AT FLOOR BEAM AT STA 4900 BL ZERO. CONNECTION AND COUPLING ANGLES REPAIRED PER SRM IPC-53-15-05, ITEM 90, FIGURE 23, AND FOKKER REPAIR REF NRT J96-61467. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
YYC - DURING FC-06 CHECK, FOUND 30 MM BY 20 MM CORRODED AREA AT FLOOR BEAM AT STA 4900 BL ZERO. CONNECTION AND COUPLING ANGLES REPAIRED PER SRM IPC-53-15-05, ITEM 90, FIGURE 23, AND FOKKER REPAIR REF NRT J96-61467. (X)