What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .75 INCH CRACK STATION 578 STUB BEAM WEB LBL 61.5 TO LBL 62.5, WL 207.5. INSTALLED DOUBLER, REPAIRED PER SRM 51-40-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .75 INCH CRACK STATION 578 STUB BEAM WEB LBL 61.5 TO LBL 62.5, WL 207.5. INSTALLED DOUBLER, REPAIRED PER SRM 51-40-2. (M)