What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK STATION 663 BULKHEAD UPPER CHORD ANGLE AT LBL 25, WL 202. INSTALLED DOUBLER, REPAIRED PER DRAWING 65C37732. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK STATION 663 BULKHEAD UPPER CHORD ANGLE AT LBL 25, WL 202. INSTALLED DOUBLER, REPAIRED PER DRAWING 65C37732. (M)