What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK STATION 597 STUB BEAM WEB RBL 60 TO RBL 62, WL 207.5. INSTALLED DOUBLER, REPAIRED PER SRM 51-40-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK STATION 597 STUB BEAM WEB RBL 60 TO RBL 62, WL 207.5. INSTALLED DOUBLER, REPAIRED PER SRM 51-40-2. (M)