What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CRACKED FRAME .75 INCH LONG STATION 727 JUST BELOW STRINGER 13L. INSTALLED REPAIR DOUBLERS, REPAIRED PER EA 51489. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CRACKED FRAME .75 INCH LONG STATION 727 JUST BELOW STRINGER 13L. INSTALLED REPAIR DOUBLERS, REPAIRED PER EA 51489. (M)