What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .125 INCH BY 1 INCH CORRODED AREA CENTER SECTION SPAR CLEVIS LUG LEFT UPPER HORIZONTAL STABILIZER. INSTALLED OVERSIZED BUSHING, REPAIRED PER EA 43494. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .125 INCH BY 1 INCH CORRODED AREA CENTER SECTION SPAR CLEVIS LUG LEFT UPPER HORIZONTAL STABILIZER. INSTALLED OVERSIZED BUSHING, REPAIRED PER EA 43494. (M)