What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .125 INCH BY 1 INCH CORRODED AREA CENTER SECTION FRONT SPAR CLEVIS LUG BORE RT HORIZONTAL UPPER STABILIZER. INSTALLED OVERSIZED BUSHING, REPAIRED PER 43494. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .125 INCH BY 1 INCH CORRODED AREA CENTER SECTION FRONT SPAR CLEVIS LUG BORE RT HORIZONTAL UPPER STABILIZER. INSTALLED OVERSIZED BUSHING, REPAIRED PER 43494. (M)