What was found
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND CORROSION ALONG UPPER 'T' CAP OF FLOORBEAM BS 345, LBL 60 TO RBL 60 WL 208. INSTALLED 'T' CAP ON FLOORBEAM PER TR 53-15-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND CORROSION ALONG UPPER 'T' CAP OF FLOORBEAM BS 345, LBL 60 TO RBL 60 WL 208. INSTALLED 'T' CAP ON FLOORBEAM PER TR 53-15-01. (M)