What was found
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND HEAVY CORROSION BETWEEN STATION 1436 AND 1456 STRINGER 28R. CORROSION TASK NR C53-155-02. REPAIRED STRINGER PER SRM 51-40-02 REF EA 62729 AND SRM 51-40-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND HEAVY CORROSION BETWEEN STATION 1436 AND 1456 STRINGER 28R. CORROSION TASK NR C53-155-02. REPAIRED STRINGER PER SRM 51-40-02 REF EA 62729 AND SRM 51-40-03. (M)