What was found
PIT - DURING C-4 CHECK, FOUND 1.5 INCH LONG CRACK IN SERVICE DOOR PAN AT NR 6 HORIZONTAL BEAM AFT END. SPLICED IN NEW PAN SECTION PER SRM 52-05 FIG 27 VIEW T-T. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING C-4 CHECK, FOUND 1.5 INCH LONG CRACK IN SERVICE DOOR PAN AT NR 6 HORIZONTAL BEAM AFT END. SPLICED IN NEW PAN SECTION PER SRM 52-05 FIG 27 VIEW T-T. (M)