What was found
PIT - DURING C-CHECK, FOUND 1 INCH CRACK IN FORWARD SERVICE DOOR PAN AFT SIDE AT HORIZONTAL BEAM END NR 6. INSTALLED PAN SPLICE (-39) PER SRM 52-05 FIG 27. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING C-CHECK, FOUND 1 INCH CRACK IN FORWARD SERVICE DOOR PAN AFT SIDE AT HORIZONTAL BEAM END NR 6. INSTALLED PAN SPLICE (-39) PER SRM 52-05 FIG 27. (M)