What was found
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 520 LBL 46 FLOORBEAM. FABRICATED REPAIRED PER EA 64448 AND S/B 737-53-1120. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 520 LBL 46 FLOORBEAM. FABRICATED REPAIRED PER EA 64448 AND S/B 737-53-1120. (M)