What was found
PIT - DURING TURN AROUND MAINTENANCE, FOUND 2 INCH BY 2 INCH CRACK, TRIANGLE OF METAL SKIN MISSING AT TOP OF LOWER HINGE CUTOUT FORWARD EDGE L2 DOOR. INSTALLED FILLER AND DOUBLER AND BLIND FASTENERS PER EA 64602. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING TURN AROUND MAINTENANCE, FOUND 2 INCH BY 2 INCH CRACK, TRIANGLE OF METAL SKIN MISSING AT TOP OF LOWER HINGE CUTOUT FORWARD EDGE L2 DOOR. INSTALLED FILLER AND DOUBLER AND BLIND FASTENERS PER EA 64602. (M)