What was found
CLT - DURING CX CHECK, FOUND STRINGER 5 LT CRACKED 1 INCH AT STATION 1142. STOP DRILLED, USED .1875 HI-LOCK FOR REAMED HOLES FOR INSTALLED ANGLE PER SRM 51-10-02 AND EA 64489. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING CX CHECK, FOUND STRINGER 5 LT CRACKED 1 INCH AT STATION 1142. STOP DRILLED, USED .1875 HI-LOCK FOR REAMED HOLES FOR INSTALLED ANGLE PER SRM 51-10-02 AND EA 64489. (M)