As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PIT - DURING Q2 CHECK, FOUND CORROSION AT STATION 205 AT AFT SIDE OF SERVICE DOOR 2 INCH BY 3 INCH AT STATION 205 LONG 18 CUSP AREA. CORROSION LEVEL 1, CORROSION TASK NR C46-53301. INSTALLED NEW CUSP MEMBRANE AND SPLICED DOOR PAN PER SRM 53-05 SIG 55 AND EA 53042.