What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 20 INCH AREA OF CORROSION AT RT AFT SERVICE DOOR Z-ANGLE (FLOOR), CORROSION LEVEL 2, CORROSION TASK NR C53-107-02. REPLACED Z-ANGLE PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 20 INCH AREA OF CORROSION AT RT AFT SERVICE DOOR Z-ANGLE (FLOOR), CORROSION LEVEL 2, CORROSION TASK NR C53-107-02. REPLACED Z-ANGLE PER SRM 51-10-02. (M)