What was found
TASK 55-10-01-290, "HORIZONTAL STABILIZER RIB LOCATION BORESCOPE INSPECTION", CRACKS WERE FOUND TO THE RIBS. LT HORIZONTAL STAB RIBS, FS 521.084, SS18.60 HAS 1 CRACK, FS 521.084, SS 37.20 HAS 1 CRACK, FS 521.084, SS 47.96 HAS 4 CRACKS & FS 521.084, SS 58.75 HAS 2 CRACKS. RT HORIZONTAL STAB RIBS, FS 521.084, SS 18.60, FS 521.084, SS 47.96 HAS 4 CRACKS & FS 521.084, SS 58.75 HAS 3 CRACKS.