What was found
LEFT OVERWING EMERGENCY EXIT DOOR LIGHT DOESN'T TURN AMBER WHEN OPENED. ADJUSTED LT OVERWING EMERGENCY EXIT PROXIMITY SWITCH IAW AMM 52-70-10, OPERATIONS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT OVERWING EMERGENCY EXIT DOOR LIGHT DOESN'T TURN AMBER WHEN OPENED. ADJUSTED LT OVERWING EMERGENCY EXIT PROXIMITY SWITCH IAW AMM 52-70-10, OPERATIONS CHECKED GOOD.