What was found
LEFT LOWER COWL GANG DRAIN PANEL GOUGED. BLENDED DAMAGE, FOUND TO BE OUT OF LIMITS. FABRICATED & INSTALLED DOUBLER IAW SRM 54-23-00, 51-42-06, 51-25-06 & AMM 51-21-10. NDT PERFORMED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT LOWER COWL GANG DRAIN PANEL GOUGED. BLENDED DAMAGE, FOUND TO BE OUT OF LIMITS. FABRICATED & INSTALLED DOUBLER IAW SRM 54-23-00, 51-42-06, 51-25-06 & AMM 51-21-10. NDT PERFORMED.