What was found
DISASSEMBLED NLG DURING SCHEDULED MAINT AND FOUND SIGNIFICANT CORROSION OVER MOST OF THE NOSE LANDING GEAR V BRACE, PN 50-820204. WE ALSO FOUND A CRACK OF 0.008 INCH IN THE NOSE BARREL, PN 99-820100-5, WHERE IT LOOKED LIKE IT HAD BEEN REPAIRED IN THE PAST. WE ALSO FOUND A CRACK OF 0.020 INCH IN THE V BRACE, PN 99-810028-989, OF THE LT LANDING GEAR.