Service difficulty report · Priority Valve · Cndair CL6002B19

Difficulty date
December 25, 2008
Submitted
December 30, 2008
Operation
Air carrier
Aircraft
N259PS
Make and model
Cndair CL6002B19
Aircraft serial
7939
Aircraft time
10,834 hours, 11,283 cycles
Part
Priority Valve
Part number
4622
Part serial
1768A
Condition
Failed
Location
Mlg
Part time
10,834 hours
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED THE GEAR DISAGREE WARNING MSG ON APPROACH TO CVG. THE CREW CYCLED GEAR HANDLE & RECEIVED MSG AGAIN & THEN IT DISAPPEARED. MAINTENANCE REMOVED & REPLACED NLG PRIORITY VALVE AND GEAR SWING WAS ACCOMPLISHED. CHECKS WERE DONE PER THE MANUFACTURERS MAINTENANCE MANUAL WITH NO DEFECTS NOTED. ACFT WAS RELEASED FOR SERVICE.