What was found
FOUND CORROSION ON INBD AFT WARDROBE FLOOR FITTING MEASURING APPROXIMATELY 0.040" DEEP LOCATED AT BS 310, LBL 20. INSTALLED A NEW SERVICEABLE FLOOR MOUNT IAW SRM 51-40-11-001-001-A01, AND 51-42-21-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON INBD AFT WARDROBE FLOOR FITTING MEASURING APPROXIMATELY 0.040" DEEP LOCATED AT BS 310, LBL 20. INSTALLED A NEW SERVICEABLE FLOOR MOUNT IAW SRM 51-40-11-001-001-A01, AND 51-42-21-001-001-A01.