What was found
WHILE PERFORMING EA 45-2018-109 P1, STEP 6, AND NDTM PART 1, 51-20-06, FOUND MULTIPLE CRACK INDICATIONS APPROXIMATELY .15 INCH LONG FROM CUTOUT HOLE. REPAIRED THE LT PRESSURE FLOOR SILL IAW EA 45-2018-109.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE PERFORMING EA 45-2018-109 P1, STEP 6, AND NDTM PART 1, 51-20-06, FOUND MULTIPLE CRACK INDICATIONS APPROXIMATELY .15 INCH LONG FROM CUTOUT HOLE. REPAIRED THE LT PRESSURE FLOOR SILL IAW EA 45-2018-109.