What was found
PAX DOOR FWD WEB FOUND TO BE CORRODED. REMOVED SUPPORT ANGLES AND NUTPLATES FROM DAMAGED PAX DOOR FWD WEB IAW CRJ 700 SRM 51-42-06/13/21-001-001-A01 REV 37. LOCATED, DRILLED UP, INSTALLED NUTPLATES & SUPPORT ANGLES ON NEW PAX DOOR FWD WEB PN 601R317071-128 IAW CRJ 700 SRM 51-40-11-001-001-A01 & 51-42-06/13/21-001-001-A01 REV 37. . REF MWC 21007211/121 FOR PAX DOOR AFT WEB INSTALLATION AND OPS CHECK OF PAX DOOR. PAX DOOR FWD WEB STEP NUTPLATE HOLES REQUIRE LOCATE/DRILLE AND NUTPLATES REQUIRE INSTALL. LOCATED, DRILLED AND INSTALLED NUTPLATES ONE FWD WEB IAW CRJ 700 SRM 51-40-11-001-001-A01 & 51-42-15-001-001-A01 REV 37 08/15/19 FOR STEP PNLS. REMOVED PAX DOOR FWD COUNTERBALANCE IAW CRJ 700 AMM 52-11-17-000