What was found
PAX DOOR STEP AFT STRUCTURE CRACKED AT 4 LOCATIONS 6TH, 5TH, 4TH AND SECOND STEPS IN CORNERS. REMOVED AFT COUNTER BALANCE SYSTEM IAW AMM 52-11-17-000-802. REINSTALLED SAME SERVICEABLE AFT COUNTER BALANCE SYSTEM IAW AMM 52-11-17-400-802-A01, STEPS 1.A THROUGH 4.A.13. REMOVED AFT COUNTER BALANCE MOUNT IAW SRM 51-42-06-001-A01. INSTALLED AFT COUNTER BALANCE MOUNT IAW SRM 51-42-06-001-001-A01. REMOVED STEP IAW SRM 51-42-21-001-001-A01. REINSTALLED CENTER STEP ASSY IAW SRM 51-42-21-001-001-A01. REPAIR REQUIRED FOR STEP 6, ZONE 1 OF AFT WEB. CUTOUT DAMAGED AREA OF STEP 6, ZONE 1 OF AFT WEB IAW SRM 52-11-04-201-004-A01. NDT REQUIRED FOR CUTOUT IAW SRM 52-11-04-201-004-A01. PERFORMED EDDY CURRENT OF CUTLINE EDGES OF ZONE 1 IAW SRM 52-11-04-201-004-A01, PAGE 209, STEP 2. NO INDICATIONS NOTED AT THIS TIME. 4TH AND 5TH (ZONE 2,3 AND 4) REQUIRES REPAIR. REFERENCE JOB 21534341, OP 93 FOR WORK PERFORMED.