What was found
DURING OVERNIGHT MAINTENANCE, A DENT WAS DISCOVERED ON THE RH FUSELAGE SKIN JUST FORWARD OF FS 220 ABOVE THE RH PITOT PROBE BETWEEN STGR 13A AND 14A. THE DENT MEASURES 2.05Ï¿½ X 2.0Ï¿½ X 0.016Ï¿½ DEEP AND IS NOT WITHIN ALLOWABLE DAMAGE LIMITS DUE TO EDGE OF DENT BEING WITHIN 1Ï¿½ OF THE FASTENERS AT FS 220. PERFORMED EA 20-C7-53-039 REV A SECTION II ITEM 4 ECI OF DISCREPANT AREA IN ACCORDANCE WITH NDTM 51-20-006, NO CRACKS FOUND. PERFORMED EA 20-C7-53-039 REV. A SECTION II ITEMS 1-3 AND 5. NO FURTHER DEFECTS FOUND AT THIS TIME.