What was found
WITH BOTH PACKS ON, GOT SMOKE IN LAST 3 ROWS OF CABIN AND IN COCKPIT WITH A BURNING PAPER SMELL. PACKS WERE ON APU BLEED AIR / PERFORMED FIM STEPS OF SMOKE AND/ ABNORMAL SMELL IN THE COCKPIT AND CABIN IAW CRJ 700 FIM 21-21-00-810-806(CONFIG A01) AND FIM 21-22-00-810-806(CONFIG A01) RESPECTIVELY. PERFORMED OPS. TEST OF AIR CONDITIONING DISTRIBUTION SYS. PER AMM 700 AMM 21-51-00-710-801. OPS. TEST IS GOOD.