Service difficulty report · Window · Cndair CL6002C10

Difficulty date
November 27, 2021
Submitted
December 1, 2021
Operation
Air carrier
Aircraft
N702PS
Make and model
Cndair CL6002C10
Aircraft serial
10135
Aircraft time
39,901 hours, 38,533 cycles
Part
Window
Condition
Arced
Component
Side Window · Ppg
Component part number
NP13932211
Stage of operation
DE
How discovered
V
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CA SIDE WINDOW ARCING AT BOTTOM, APPROX 8-10 INCHES FROM PILLAR, CYCLED LH WINDOW HEAT, ARCING LESS INTENSE, ARCING STOPPED ONCE UNDER 15K FEET / DEFERRED LH SIDE WINDOW HEATING SYSTEM PER MEL 30-41-02 CAT A. DEACTIVATED LH SIDE WINDOW HEAT CONTROLLER BY PULLING AND COLLARING CBP-1 U10 & CBP-2 S4. PERFORMED REMOVAL OF L.H. FLIGHT COMPARTMENT SIDE WINDOW IAW CRJ 700 AMM 56-12-01-001-801-A01-PSA. INSTALLED LH FLIGHT COMPARTMENT SIDE WINDOW IAW CRJ 700 AMM 56-12-01-400-801-A01-PSA REV C UP TO STEP 5(D). OPS CHECK GOOD. STEP 5(E)-5(H) NEED TO BE C/W.COMPLIED WITH STEPS 5(E) IAW CRJ 700 AMM 56-12-01-400-801-A01-PSA. LEAK CHECK GOOD AT THIS TIME.