What was found
MULTIPLE BRAKE OVHT WARNINGS IN FLIGHT RAN QRH MESSAGE EXTINGUISHED. DEFERRED RH OB BTMSPER CRJ 700 MEL 32-46-01 CAT C. M FUNCTION C/W BY PLACING HIGH TEMP LACING TAPE OVER CONNECTOR AND ZIPTIE THE CANON PLUG. PLACE PLACARD/STICKER ON SECONDARY EICAS DISPLAY. INSULATION AND CONTINUITY CHECKED GOOD. REMOVED AND REPLACED MLG WOW PROX SENSOR HARNESS IAW CRJ 700 AMM 32-61-05-000/400-803. BITE/OPS TEST OF TEMP MONITORING SYSTEM GOOD.REQUIRES ADJUSTMENTS OF RH OB PROX SENSOR. PREFORMED ADJUSTMENTS OF RH OB PROX SENSOR (WOW) OPS CHECK GOOD. IAW CRJ 700 AMM 32-61-05-820-803."