What was found
EMERGENCY FLOOR PATH LIGHTING APPEARS TO BE WRONG EFFECTIVITY / REMOVED IMPROPER FLOOR-PATH MARKING AND PARTIALLY INSTALLED CORRECT FLOOR-PATH MARKING THAT WAS AVAILABLE FROM GALLEY TO SEAT 3FD ON RIGHT SIDE. ON LEFT SIDE INSTALLED FROM GALLEY TO SEAT 3A IAW CRJ 700 AMM 33-51-01-000/400-801-A79. REMOVED IMPROPER EMERGENCY FLOOR PATH MARKING AND PATIALLY INSTALLED CORRECT FLOOR PATH MARKING THAT WAS AVAILABLE L/H SIDE FROM SEAT 21C/A TO 16C/A FROM EMERGENCY EXIT ROW TO SEAT ROW 3A NEEDS COMPLETED. ON R/H SIDE INSTALLED CORRECT FLOOR PATH MARKING FROM SEAT 21F/D TO 18F/D FROM SEAT 18F/D TO SEAT 3F/D NEEDS COMPLETED IAW CRJ 700 AMM 33-51-01-000/400-801-A79. REMOVED IMPROPER EMERGENCY FLOOR PATH MARKING AND PATIALLY INSTALLED CORRECT FLOOR PATH MARKING THAT WAS AVAILABLE L/H SIDE REMAIN SECTIONS COMPLETED ON R/H SIDE INSTALLED CORRECT FLOOR PATH MARKING FROM SEAT 18F/D TO 17F/D AND SEAT 3FD TO 13FD SEATS 14FD TO 6FD AND RIGHT HAD EXIT ROW STILL NEEDS COMPLETED IAW CRJ 700 AMM 33-51-01-000/400-801-A79. INSTALLED CORRECT EMERGENCY PATH LIGHTING FROM SEATS 14FD TO 6FD AND RIGHT HAND EXIT ROW IAW CRJ 700 AMM 33ˆ’51ˆ’01ˆ’400ˆ’801ˆ’A01ˆ’PSA. OPS CHECK GOOD