What was found
DUAL R ENG FADEC FAULT RESULTING IN R ENG FLAMEOUT DURING CLIMB. HAD SUCCESSFUL AUTO RE-LIGHT. PREFORMED A VISUALLY CHECK OF RH FADEC AND MADE SURE ALL CONNECTORS ARE SECURED, NO DEFECTS NOTED. PERFORMED A POWER ON BUILT IN TEST IAW CRJ900 AMM 71-00-00-710-801. OPS CHECK GOOD. SUSPECT RH FADEC DUE TO SUCCESSFUL AUTO RE-LIGHT AND PREFORMED WITH NO DEFECTS ONCE CHANNELS WHERE SWITCHED. REMOVED AND REPLACED RH FADEC IAW CRJ900 AMM 73ˆ’21ˆ’01ˆ’000/400ˆ’801. OPS CHECK GOOD. THREE SUCCESSFUL ENGINE STARTS WITH IDLE RUN.