BRAKE OVERHEAT MESSAGE ON CLIMBOUT IN DCA / DEFERRED RH OB BTMS PER MEL 32-46-01 CAT C. OPTION 4. M-FUNCTION C/W CAPPED AND STOWED HARNESS CONNECTOR AND CAPPED THERMOCOUPLE CONNECTOR. BRAKE OVERHEAT MESSAGE ON CLIMBOUT IN DCA / REMOVED AND REPLACED #4 BRAKE ASSY IAW CRJ 700 AMM 32-43-26-000/400-801-A01-PSA. OPS CHECK GOOD. LEAK CHECK GOOD. BREAK TEMPERATURE INDICATION IS GOOD AT THIS TIME. THIS CLEARS MEL. NO CURRENT DEFECTS NOTED AT THIS TIME.