- Difficulty date
- March 10, 2024
- Submitted
- March 13, 2024
- Operation
- Air carrier
- Make and model
- Cndair CL6002C10
- Aircraft serial
- 10053
- Aircraft time
- 46,450 hours, 35,462 cycles
- Part
- Probe
- Part number
- 6007300
- Condition
- Faulted
- Location
- Brake Overheat
- Stage of operation
- CL
- How discovered
- O
- Nature of condition
- N
- Precautionary procedure
- A
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BRAKE OVHT WARNING MSG IN FLIGHT, L OUTBD SENSOR APPEARS ERRONEOUS AT 20 / PERFORMED TROUBLESHOOTING OF BRAKE OVHT WARNING MSG IAW FIM 32-46-01-810-802 A01. REMOVED LH OB THERMOCOUPLE SENSOR IAW 32-46-01-000-801 A01. REPLACED LH OB THERMOCOUPLE SENSOR IAW CRJ700 32-46-01-400-801-A01 PSA. OPS CHECK GOOD.