Service difficulty report · Condenser · Cndair CL6002D24

Difficulty date
September 28, 2024
Submitted
October 1, 2024
Operation
Air carrier
Aircraft
N631NN
Make and model
Cndair CL6002D24
Aircraft serial
15376
Aircraft time
18,077 hours, 13,937 cycles
Part
Condenser
Part number
GG47420533
Part serial
00604
Condition
Failed
Location
Zone 100
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT BLEED WARNING/ CAUTION MSG WITH L PACK AUTO SHUTDOWN. LOSS OF PRESSURIZATION. / REMOVED AND REPLACED THE LH PRECOOLER IAW CRJ 900 AMM 21-53-04-000/400-801-A05. REMOVED AND REPLACED THE RH CONDENSER/REHEATER IAW CRJ900 AMM 21-51-14-000/400-801(A01). PERFORMED LEAK CHECK IAW CRJ 900 AMM 21-51-00-790-801. LEAK CHECK GOOD AT THIS TIME.