As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON HOUSING (6EAS) OF HINGE FITTINGS 2,3,4 (OUTBD AND INBD) AT RH WING REAR SPAR. HOUSNGS OF HINGE FITTINGS 2 & 3 (OUTBD AND INBD) AT RH WING REAR SPAR WERE CLEANED PER CRJ 700/900 SRM 51-12-00-001-001-A01 AND HOLE OF HINGE 4 WERE REPAIRED PER REO REO REO 690-57-51-429 REV -