What was found
OVERHEAD BIN AT 15AC NOT ALLOWING FWD AND AFT EMERGENCY EXITS TO OPEN FOR EGRESS / PERFORMED ADJUSTMENT OF THE RODS OF THE OVERHEAD STORAGE COMPARTMENT INSTALLED ABOVE THE OVERWING EMERGENCY EXIT ON OVERHEAD BIN AT SEATS 15,16AC IAW AMM 25-23-00-820-803. INSTALLED OVERHEAD BIN IAW AMM 25-23-01-400-801-A50-PSA. OPS CHECKS GOOD AT THIS TIME. VERIFIED OVERWING EMERGENCY EXIT DOORS TO CLEAR AND OPEN.