What was found
CRACK ON FLOOR SUPPORT RBL 12, BTWN BS 221.73 - 229 AT FWD FUSELAGE INTERNAL STRUCTURE, FLIGHT COMPARTMENT FLOOR STRUCTURE BELOW WL 79.50. FLOOR SUPPORT AT FWD FUSELAGE INTERNAL STRUCTURE WAS REPAIRED IAW REO 690-53-11-2229, REV --.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON FLOOR SUPPORT RBL 12, BTWN BS 221.73 - 229 AT FWD FUSELAGE INTERNAL STRUCTURE, FLIGHT COMPARTMENT FLOOR STRUCTURE BELOW WL 79.50. FLOOR SUPPORT AT FWD FUSELAGE INTERNAL STRUCTURE WAS REPAIRED IAW REO 690-53-11-2229, REV --.