What was found
TEMP REPAIR FOR DAMAGE TO LH PYLON UPPER CANTED RIB BETWEEN FS1069.75 - FS1088.20 THIS TEMPORARY REPAIR IS STRUCTURALLY ACCEPTABLE FOR 8000 FLIGHT HOURS FROM TIME OF INCORPORATION OF THIS REO AT REV "-" PERFORM A PERMANENT REPAIR IAW APPROVED PROCEDURES. // ENGINEERING COMMENTS: A PERMANENT REO HAS BEEN ISSUED FOR 85693 RFTS-130142 FOR THE CANTED RIB. THIS IS FOR AN IN SERVICE A/C AND HAS BEEN PROVIDED AS A PERMANENT SOLUTION FOR A TEMP REO UNDER TRFKE00BZNWL. REPAIR TO LH PYLON UPPER CANTED RIB BETWEEN BS 1069.75 - 1088.20 WAS CONSIDERED AS PERMANENT PER REO 690-54-51-047 REV -B.