As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EXPERIENCED AN ELECTRICAL BURNING ODOR IN THE FLIGHT DECK. THE FLIGHT CREW FOLLOWED FCOM PROCEDURES AND CONTINUED TO DESTINATION. TSM 24-11-00-810-823A & 21-26-00-810-809A WERE ACCOMPLISHED. THE AVIONICS EXTRACT FAN 18HQ WAS FOUND FAILED AND DEACTIVATED. MEL 21-26-02-03 WAS APPLIED AND THE ACFT WAS RETURNED TO SERVICE. NO FURTHER PROBLEMS REPORTED ON SUBSEQUENT FLIGHTS.