What was found
FLT 6572 - IAD-SCE - DURING TAKEOFF, THE CREW EXPERIENCED A NLG INTRANSIT LIGHT THAT REMAINED ON. A/C RETURNED TO IAD WHERE MX CONTROL WAS NOTIFIED AND DISPATCHED MAINTENANCE. MAINTENANCE INSPECTED THE NOSE LANDING GEAR SYSTEM IAW MM AND FOUND THAT THE ROD ENDS ATTACHED TO THE GEAR LEG ASSY NEEDED TO BE ADJUSTED. A/C WAS MOVED TO THE HANGAR WHERE THE ROD ENDS WERE ADJUSTED AND THE LANDING GEAR WAS FUNCTIONALLY CHECKED FOR PROPER OPERATION. ALL CHECKS WERE SATISFACTORY AND AIRCRAFT WAS RELEASED FOR SERVICE. (M)