SDR WRLA200410

Service difficulty report · Controller · Doug DC1030F

Difficulty date
February 28, 2004
Submitted
March 6, 2004
Operation
Air carrier
Aircraft
N303WL
Make and model
Doug DC1030F
Aircraft serial
46917
Part
Controller
Condition
Intermittent
Location
A/C Pack
Component
A/C Pack · Garrettltd
Component part number
6179246
Stage of operation
CL
How discovered
C
Nature of condition
B, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SMOKE IN COCKPIT AFTER TAKE OFF TURNED NR 2 PACK OFF. SMOKE STOPED.RETURNED TO BGR. NOTE INSPECTED PACK & ON OPS TEMP DISCHARGE TEMP 95 PERCENT PACK AUTO OFF PLACED NR 2 PACK ON DMI M21FE2704-124 MEL 21-1 CAT C.. CLEARED DMI M21FE2704 REMOVED AND REPLACED NR 2 PACK TEMP CONTROLLER RAN NR 2 PACK ON GROUND FOR MAINY HOURS & PACK TEMP OPS NORMAL ALL PARAMETERS SHOW NORMAL AT THIS TIME ON GROUND.