What was found
DURING C-CHK IN TPE, INSPECTION FOUND CORROSION ON FWD MAIN DECK CABIN, RT-3 DOOR JAMB INTERNAL SKIN CORROSION AT STA 1302 AND L25R-L26R (EGAT NRC U05089). REPAIRED MAIN DECK CABIN R-3 DOOR JAMB SKIN AT Y= 1302 & X= 25R-26R IAW MD-11F SRM VOL 1, 53-50-00 FIG 18 (SHEET 1 & 4) REV 40. CONDITION CHECK NORMAL & JOB COMPLETE.