What was found
LEFT OIL PRESS, HYD PRESS, HYD QTY & FLAP IND DISPLAYED DASHES CB K9 LT INSTRUMENT TRANSFER POPPED. CALLED MX CONTROL & INSTRUCTED DO NOT RESET. DID AIR RETURN IAW DISPATCH. REPLACED LT INSTRUMENT TRANSFORMER. OPERATIONS CHECKED GOOD IAW AMM 24-00-00 & 77-42-00. 8/5/14 COULD NOT DUPLICATE BUT REPLACED LT INSTRUMENT TRANSFORMER T1-19 THAT CONTROLS ALL OF THOSE SYSTEMS. NO REPEATS.