What was found
ON CLIMB OUT, PLATFORM 1 DATA FAIL, FIRST OFFICERS ATTITUDE INDICATOR WAS NOT STABLE & WAS ERRATIC. AUTOPILOT & AUTO THROTTLE DISENGAGED, THEN RE-ENGAGED. PROBLEM REPEATED, SWITCHED AUTOPILOT TO NR 1. FIRST OFFICERS ATTITUDE INDICATOR STILL INTERMITTENTLY ERRATIC, AUTOPILOT & ANTI-THROTTLE STAYED ENGAGED. REF LOG PAGE 677431 FOR TROUBLESHOOTING PERFORMED. CONTINUED TROUBLESHOOTING IAW AMM 22-01-05, WITH NO DEFECTS FOUND. PAGE 33 SHOWS INTERMITTENT FAILURE OF AC EMER POWER TRANSFER RELAY CAN CAUSE PLATFORM 1 & OR 2 DATA FAILURE. R & R RELAY PRECAUTIONARY IAW AWDM 24-23-00. PERFORMED RTS WITH GO ON BOTH SYSTEMS IAW AMM 22-01-05.