What was found
MHV - DURING AIRCRAFT SCHEDULED INSPECTION AT REPAIR STATION, NDT HFEC INSPECTION DETECTED CRACK OF APPROXIMATELY 2 INCH LONG ON SHEER CLIP BETWEEN LONGERON L15 AND L16 AT FUSELAGE STATION 766. FABRICATED REPAIR SHEER CLIP. REMOVED CRACKED SHEER CLIP AND INSTALLED REPAIRED SHEERCLIP IAW DC-9 SRM 51-10-1, 51-10-3 AND 51-30-2. (M)